Skip to content

Official European representation of the Akrilika solid surface factory · Supply to projects across Europe

Request a quote → WhatsApp E-mail

Specification

Certifications and test data

Fire class for walls and ceilings, indoor air, disinfectants, food contact and kitchen and bathroom surface tests. Each result is given with the lab, the standard, the report number and the year, and with its document status as of September 2026.

Wall and ceiling cladding, 12.3 mm, EN 13501-1 (ITB)
B-s1,d0
Wall and ceiling cladding, 6 mm, EN 13501-1 (ITB)
C-s1,d0
Water vapour resistance factor, ITB 2018
> 50 000μ
Kitchen and bath surfaces, TÜV Rheinland 2016
2 PfG-Q 2418
3D visualisation: close-up of a seamless joint between an integrated basin and worktop
PDF Documents

Download the documents

Complete, unmodified copies of the certificates, test reports and data sheets. A test report has no expiry date; a certificate or assessment is valid for a period, and expired ones are marked.

  • PDF

    ITB national technical assessment (KOT): wall and ceiling cladding Expired Mar 31, 2026

    ITBNo. ITB-KOT-2021/1061Mar 31, 2021PLPDF, 6.8 MB

    Download PDF
  • PDF

    ITB test report: water vapour permeability Test report

    ITBNo. LZM02-01702/17/Z00NZMJan 16, 2018PLPDF, 806.1 kB

    Download PDF
  • PDF

    TÜV Rheinland test reports: kitchen and bath surfaces, slip, chemicals, fire Test report

    TÜV RheinlandNo. 21255144_001, 21255145_001, 21255146_001, 21245130_001–0032015–2016DE / ENPDF, 4.9 MB

    Download PDF
  • PDF

    NIZP-PZH hygiene certificate and metal-release test report Expired Aug 3, 2019

    NIZP-PZHNo. H-HŻ-6071-179/16/D; 038/106/16/LHŻ/D2016PL / ENPDF, 2.0 MB

    Download PDF
  • PDF

    Akrilika technical data sheet Data sheet

    TÜV Rheinland, SGS-CSTC, NIZP-PZH2016DE / EN / RUPDF, 328.6 kB

    Download PDF
  • PDF

    Apietra technical data sheet Data sheet

    TÜV Rheinland, SGS-CSTC2016DE / EN / RUPDF, 378.2 kB

    Download PDF
  • PDF

    AQ Stone quartz technical data sheet Data sheet

    SNQS & TC, TÜV SÜDNo. SCW20150160-1; 7191036694-MEC12-1B-NLH2012–2015DE / EN / RUPDF, 200.4 kB

    Download PDF
  • PDF

    ISFA membership certificate 2024–2025 Expired Feb 2025

    ISFA2024ENPDF, 474.4 kB

    Download PDF
  • PDF

    Care instructions for sinks and basins Care guide

    AkrilikaPLPDF, 561.3 kB

    Download PDF

Test results stay relevant while the composition and production of the material are unchanged. For anything not listed here, such as a food-contact report summary or a document dated within a set period, contact us.

Contents
  1. Document status at a glance
  2. Fire: wall and ceiling cladding
  3. Fire: the TÜV and SGS results, and how not to use them
  4. Indoor air: VOC emissions
  5. Moisture and vapour
  6. Disinfectants and cleaning chemicals
  7. Food contact
  8. Kitchen and bathroom surfaces: TÜV Rheinland 2 PfG-Q 2418
  9. Physical properties
  10. Limits: where not to use it
  11. Technical documents available on request

This page collects the compliance evidence for Akrilika acrylic solid surface, Apietra and AQ Stone quartz, in the form a fire engineer, infection-control lead or tender reviewer needs: what was tested, by whom, to which standard, in which report and in which year. The full property tables are on the technical data page.

We keep one rule. A test report records a result and has no expiry date. A certificate or assessment is valid for a period. Where that period has ended, we say so, and we cite the tested result with its year, not as a current certificate.

Document status at a glance

Document Issued by Number Date Status (28 Sept 2026)
National technical assessment (KOT): wall and ceiling cladding, fire, VOC, properties ITB ITB-KOT-2021/1061, ed. 1 31 Mar 2021 Expired 31 Mar 2026
Test report: water vapour permeability, 6.0 and 12.3 mm ITB LZM02-01702/17/Z00NZM 16 Jan 2018 Test report, no expiry
Kitchen and bath furniture surfaces, 2 PfG-Q 2418:2015-04 TÜV Rheinland LGA Products 21255144_001 (Akrilika), 21255145_001 (Apietra), 21255146_001 (Akrilika Kristall) 2016 Test reports, no expiry
Slip, chemicals (ISO 19712-2), impact, reaction to fire (flooring methods) TÜV Rheinland 21245130_001 to _003 2015 Test reports, no expiry
Food contact: sensory and migration TÜV Rheinland on request 2016 Test report, no expiry
Physical properties, stains and chemicals (ANSI Z124.3), BS 476-7 SGS-CSTC on request 2013–2016 Test reports, no expiry
Metal release (lead, cadmium) National Institute of Public Health (NIZP-PZH), Poland 038/106/16/LHŻ/D 22 Jul 2016 Test report, no expiry
Hygiene certificate for kitchen sinks and worktops NIZP-PZH, Poland H-HŻ-6071-179/16/D 3 Aug 2016 Expired 3 Aug 2019
ISFA membership certificate (Akrilika Poland, member since 2013) International Surface Fabricators Association — Feb 2024 – Feb 2025 Period ended. We do not claim current membership.

Test results stay relevant while the composition and production of the material are unchanged. If your tender requires a document dated within a set period, tell us at the start and we will confirm what can be supplied.

Fire: wall and ceiling cladding

ITB classified Akrilika sheet to EN 13501-1:2019 as interior wall and ceiling cladding:

Thickness Class
12.3 mm B-s1,d0
6.0 mm C-s1,d0

In both classes, s1 stands for the lowest smoke production and d0 for no flaming droplets. ITB also records that the 12.3 mm sheet does not fall off in a fire.

Mounting conditions of the classification. The sheets are fixed mechanically, with steel fixings, directly to a non-combustible substrate of at least A2-s1,d0 or to plasterboard. A different build-up, such as bonding to timber or a combustible board, is outside the classification. Floors are outside the scope of the assessment.

Source and status. National technical assessment ITB-KOT-2021/1061, edition 1, issued 31 March 2021 to Akrilika Poland Sp. z o.o. Its validity ended on 31 March 2026. Quote the class with the document number and dates, and ask us about the current status before you write the clause.

Fire: the TÜV and SGS results, and how not to use them

  • Bfl-s1 to EN 13501-1 (TÜV Rheinland, 2015, report series 21245130, A101 and Apietra M601, tested on 8 mm fibre-cement). This is a flooring class, obtained with the flooring methods EN ISO 9239-1 and EN ISO 11925-2. It is not a wall class, and it must not be written as B-s1,d0. The material is not a floor covering (see limits below).
  • Class 1 surface spread of flame, BS 476-7 (SGS-CSTC).
  • Apietra oxygen index 41.6 (manufacturer’s Apietra data sheet).

Indoor air: VOC emissions

ITB assessed the emissions of volatile organic compounds to EN ISO 16000-9 and ISO 16000-3 and -6 (ITB-KOT-2021/1061, 2021):

  • The sheet is suitable for category A and B rooms under the Polish 1996 regulation (MZiOS), which cover homes, hospitals, schools and similar buildings.
  • Rooms can be used immediately after installation. Emissions reach permitted concentrations within 28 days at most.

For a hotel, clinic or school this means the cladding or tops are not a reason to delay handover.

Moisture and vapour

Property Result Standard / source
Water vapour resistance factor μ > 50 000 ITB report LZM02-01702/17/Z00NZM, 2018 (6.0 and 12.3 mm)
Equivalent air layer thickness sd > 300 m same report
Water absorption ≤ 0.1 % EN 520, ITB-KOT-2021/1061
Water absorption, 49 days immersed 0.27 % ASTM D570, SGS-CSTC
Dimensional change with humidity, and at +70 °C ± 0.1 % ITB-KOT-2021/1061

The sheet is vapour-tight. In showers, wet rooms and washrooms, plan the wall build-up with that in mind, because the cladding acts as a vapour barrier on the room side.

Disinfectants and cleaning chemicals

Test Agents Result Lab, year
ANSI Z124.3 Concentrated sodium hypochlorite, hydrogen peroxide 3 %, urea 6 %, ammonia 10 %, alcohol Pass SGS-CSTC
ANSI Z124.3 Iodine, gentian violet, lipstick, shoe polish, hair dye Pass SGS-CSTC
ISO 19712-2 Hydrogen peroxide 30 %, sodium hydroxide 25 % 5 (no change) TÜV Rheinland, 2015
ISO 19712-2 Acetone 3 TÜV Rheinland, 2015
DIN EN 12720, 16 h 21 agents, including disinfectant, wine, coffee, cola, oil, cleaning agents, petrol Mostly 5 (no change) TÜV Rheinland, 2016
DIN EN 12720, 16 h Acetone, ethyl-butyl acetate 3–4 TÜV Rheinland, 2016

Hypochlorite and hydrogen peroxide are the active agents in many clinical disinfectants, so check your product’s data sheet against this list. Do not use acetone or solvent-based cleaners. We do not claim the material is antibacterial or antimicrobial: no test such as ISO 22196 is on file.

Food contact

Tested by TÜV Rheinland in 2016, with metal release tested by the National Institute of Public Health in Poland:

  • Sensory test (odour and taste): pass, to LFGB §31 and Regulation (EC) 1935/2004.
  • Migration of acrylonitrile, formaldehyde, metals, primary aromatic amines, acrylic and methacrylic acid, and PAH: below the limits of Regulation (EU) 10/2011.
  • Colour migration of pigments: pass (BfR recommendation IX).
  • Lead and cadmium release: lead < 0.1 mg/dm² (limit 0.8), cadmium < 0.01 mg/dm² (limit 0.07). NIZP-PZH report 038/106/16/LHŻ/D, 2016.

A PZH hygiene certificate (H-HŻ-6071-179/16/D) covered solid surface kitchen sinks and worktops for kitchens and food-industry premises from 2016. It expired on 3 August 2019 and is not presented as current. The test results above remain on file.

Kitchen and bathroom surfaces: TÜV Rheinland 2 PfG-Q 2418

TÜV Rheinland LGA Products tested Akrilika (21255144_001), Apietra (21255145_001) and Akrilika Kristall 12.3 mm (21255146_001) in 2016 to 2 PfG-Q 2418:2015-04, the test programme for kitchen and bathroom furniture surfaces:

Property Akrilika Apietra Standard
Dry heat 180 °C 7A 7A DIN EN 12722
Wet heat 100 °C 8A 8A DIN EN 12721
Abrasion 2A (> 650 revolutions) 2A DIN EN 15185
Steam, hot wax (24 h) No change No change 2 PfG-Q 2418
Humid climate 14 days, 40 °C / 85 % RH No change No change 2 PfG 2507-1
Alternating climate −20 / +60 °C No change; warp 1.33 mm/m (limit 1.5) No change 2 PfG 2507-2
Graphite test (open porosity) No change — DIN EN 12720
Hot pan 185 °C, 10 min — No change manufacturer data sheet
Light fastness > 6, tested colours > 6 DIN EN 15187

Also tested on Akrilika: boiling water and steam without change (NEMA LD3, SGS-CSTC).

Physical properties

Akrilika (100 % acrylic; SGS-CSTC 2016 unless stated)

Property Result Standard
Density 1.74 g/cm³ (tolerance 1.70–1.75 in ITB-KOT) ASTM D792
Flexural strength / modulus 64.9 MPa / 11 975 MPa (ITB-KOT: ≥ 55 / ≥ 9500 MPa) ASTM D790; EN ISO 178
Tensile strength / modulus 45.6 MPa / 9840 MPa, elongation 0.66 % ASTM D638
Barcol hardness 68 ASTM D2583
Hard-body impact No damage at 1 J (6 mm) and 4 J (12.3 mm) EN 13245-1, ITB-KOT
Impact IC2 EN 13329, TÜV Rheinland

Apietra (modified acrylic, sample M601)

Property Result Standard
Density 1.72 g/cm³ ASTM D792
Flexural strength / modulus 54.9 MPa / 9680 MPa ASTM D790
Barcol hardness 66 ASTM D2583
Impact IC1 EN 13329
Reaction to fire Bfl-s1 (flooring method); oxygen index 41.6 EN 13501-1; TÜV Rheinland

AQ Stone quartz (engineered quartz, 20 mm; SNQS & TC 2015, TÜV SÜD 2012)

Property Result Standard
Apparent density 2306 kg/m³ EN 14617-1
Water absorption 0.053 % EN 14617-1
Flexural strength 70.3 MPa EN 14617-2
Compressive strength 211 MPa; 229 MPa (TÜV SÜD) EN 14617-15; ASTM C616
Impact 12.73 J EN 14617-9
Abrasion resistance 29.5 mm EN 14617-4
Mohs hardness 6 EN 101
Freeze-thaw resistance, 25 cycles 99.9 % (70.2 MPa after 25 cycles) EN 14617-5
Thermal shock resistance −1.6 %, no visual change EN 14617-6
Chemical resistance C4 EN 14617-10

Limits: where not to use it

  • Not for floors. TÜV Rheinland measured Akrilika at 4.9° under DIN 51130 (report 21245130_001), which gives no R slip-resistance class. Do not specify it for floors, steps, shower floors or decks.
  • Not for outdoor use. The manufacturer’s warranty is void for outdoor installation and for unheated rooms.
  • No acetone, no abrasive cleaners. Acetone scored 3 in chemical tests. Do not pour water above 115 °C, and run cold water when pouring boiling water into a sink. Use a trivet under hot pans.
  • Colour-dependent results. Light fastness and furniture-surface chemical grades were tested on selected colours. For sunlit areas, labs or strong colours, give us the colour code and we send the result for that colour.
  • Not a certification mark. “Tested by TÜV Rheinland” is correct. “TÜV certified” is not.

Technical documents available on request

We send the complete reports, the ITB assessment and the data sheets by e-mail for a named project. We do not publish them as downloads, because ITB and the test labs allow their documents to be reproduced only in full, and your file should hold the right edition.

Request technical documents with the project name, the report numbers from this page, the material and the colour codes. For help writing the clause, see specification support.

FAQ

Questions from specifiers

Which fire class can I quote for Akrilika wall cladding?

B-s1,d0 to EN 13501-1 for 12.3 mm sheet and C-s1,d0 for 6 mm sheet, used as interior wall and ceiling cladding and mechanically fixed with steel fixings to a non-combustible substrate (at least A2-s1,d0) or to plasterboard. The classification is given in the ITB national technical assessment ITB-KOT-2021/1061, issued on 31 March 2021. That document's validity ended on 31 March 2026, so quote it with its number and dates and ask us about the current status before tender.

Is Bfl-s1 the wall fire class?

No. Bfl-s1 is a flooring reaction-to-fire class under EN 13501-1. TÜV Rheinland obtained it in 2015 with the flooring test methods EN ISO 9239-1 and EN ISO 11925-2, on A101 and Apietra M601. Do not quote it for walls, ceilings or counter fronts. The wall and ceiling classes are the ITB results above.

Can Akrilika be used in hospitals and schools?

For indoor air, yes. ITB assessed VOC emissions (EN ISO 16000-9, ISO 16000-3 and -6) and found the sheet suitable for category A and B rooms under the Polish 1996 regulation, which covers homes, hospitals and schools. Rooms can be used straight after installation, and emissions fall within permitted levels within 28 days. Surfaces also passed concentrated sodium hypochlorite and hydrogen peroxide in lab tests.

Are the certificates still valid?

Test reports have no expiry date. They describe the material as tested, and stay relevant while its composition and production are unchanged. Three documents have expired and we do not present them as current: ITB-KOT-2021/1061 (ended 31 March 2026), the PZH hygiene certificate H-HŻ-6071-179/16/D (ended 3 August 2019) and the ISFA membership certificate for February 2024 to February 2025.

Can you send the full reports?

Yes, on request for a named project. Reports are sent as complete copies, not extracts, because the labs allow them to be reproduced only in full. Tell us the report number from this page, the material and the colour code.

→ Related

Keep specifying

Sector

Healthcare

Clinics, labs, dental surgeries, care homes

Specifying Akrilika for a project?

Project desk

Specification questions, quotes and samples for projects across Europe. Drawings welcome.

Mon–Fri, 9:00–17:00 CET

Send plans or elevations as PDF, DWG or DXF. We reply by e-mail with a written quote.